BLOBEL Doorway Spill Barrier BL/BED-PM and BL/BDD-PM, tested and approved by TUV.

Share on Social Networks

Share Link

Use permanent link to share in social media

Share with a friend

Please login to send this document by email!

Embed in your website

Select page to start with

2. Page 2 of 3 Copy – only the signed original copy is legally binding Reference, Date, Project No.: IS - BT1 - MUC , Bm / - Sj , 16/11/2018 , 1180345 - K3 - 30 / 2931886 Client: Blobel Umwelttechnik GmbH , Henleinstrasse 29a , 86368 Gersthofen, Germany Test objects: Type BL/BED - PM and Type BL/BDD - PM Order: Participation in the leak testing of mobile containment systems for firefighting water retention based on VdS Guidelines 2564 - 1 1 Basis With the letter dated 18 July 2018 , TÜV SÜD Industrie Service GmbH (TÜV SÜD) was engaged by Blobel Umwelttechnik GmbH , Henleinstrasse 29a , 86368 Gersthofen, Germany as follows: Participation in the leak testing of mobile containment systems for firefighting water retention based on VdS Guidelines 2564 - 1 , dated October 2004. 2 Actions / Notes On 22 December 2017 and 16 August 2018 measurement meetings with leak testing based on Chap. 5.8 of the VdS Guidelines 2564 - 1 took place in the factory hall - type buildings of Blobel Umwelttechnik GmbH . Once in the hall at Ziegelleistr. 5 and once at Henleinstrasse 29a each in 86368 Gersthofen, Germany . The following syst ems were examined: Type BL/BED - PM and Type BL/BDD - PM . Test sequence (based on Chap. 5.8 of the VdS Guidelines 2564 - 1):  One - hour leak test The following deviations from the leak test in accordance with Chap. 5.8 of VdS 2564 - 1 were found: 1. Substrate “Diamond height of 2 mm to DIN 59 220”: VdS 2564 - 1 specifies: “Diamond plate (checker plate) with a diamond height of 2 mm top DIN 59220 is used to simulate the substrate of the subsequent use conditions.” The dia- mond height was 1.2 mm. Products to DIN 59220 have a diamond (pattern) height of 1 mm to 2 mm. The quest ion here is therefore whether the protection objective “leaktightness” to VdS 2564 - 1 really has to be verified for a diamond height of 2 mm or 1 mm to 2 mm, i.e. whether this is a transfer error from DIN 59220. To what extent a 2 mm, i.e. 0.8 mm higher dia mond height than present actually influences the leaktightness test cannot be reliably foreseen without test- ing. But the diamond height used is standard and conforms to DIN 59220. The objective of the diamonds is to simulate the usual roughness of the subs trate in the test. This is also achieved properly by a diamond height of 1.2 mm. The diamond height is therefore repre- sentative for different roughnesses.

3. Page 3 of 3 Copy – only the signed original copy is legally binding Reference, Date, Project No.: IS - BT1 - MUC , Bm / - Sj , 16/11/2018 , 1180345 - K3 - 30 / 2931886 Client: Blobel Umwelttechnik GmbH , Henleinstrasse 29a , 86368 Gersthofen, Germany Test objects: Type BL/BED - PM and Type BL/BDD - PM Order: Participation in the leak testing of mobile containment systems for firefighting water retention based on VdS Guidelines 2564 - 1 2. Test period of the main test at least 4 h and at least 1 h for the repeat testing: A test period of 1 h was chosen instead of 4 h. A repeat test was not performed. In this case the moisture penetration was observed and no significant time changes were found. The reduction in the test period is therefore justified. 3 Test result Blobel Umwe lttechnik GmbH had the following containment systems / retention barriers success- fully tested with the following test result. Category 3: “Automatic systems, fixed, rotatable” Leak rate Verification fulfilled Test object Type Test length / height [mm] / [mm] Exist. [ml / m / h] All. [ml / m / h] Type BL/BED - PM Seal type DEP EPDM foam black / closed cell ρ  95 kg/m ³ Type BL/BDD - PM Seal type DEP EPDM foam black / closed cell ρ  95 kg/m ³ 2,500/300 2,500/300 0 37 50 50 yes yes The test showed: The containment systems / retention barriers Type BL/BED - PM and Type BL/BDD - PM conform to the leaktightness based on Chap. 5.8 of VdS 2564 - 1. Issued on 16/11/2018 TÜV S ÜD Industrie Service GmbH Civil engineering Munich Expert gez. gez. Dipl. Ing. Martin Kneißl Dipl. - Ing. Martin Beike

1. Copy – only the signed original copy is legally binding Date: 16/11/2018 Reference: IS - BT1 - MUC / Bm Document: 1180345 - K3 - 30_BTG_Fa Blobel_Prufung - Dichtheit_Störfallsysteme _TYPE N BED_EN.docx The document consists of 4 pages . Page 1 of 4 Reproducing excerpts from this document and use for advertising purposes require the written con- sent of TÜV SÜD Industrie Service GmbH. Die Prüfergebnisse beziehen sich ausschließlich auf die untersuchten Prüfgegenstände. Registered office: Munich Munich District Court HRB 96 869 VAT No. DE129484218 Information pursuant to Clause 2 Para 1 DL - InfoV (Germany) at www.tuev - sued.de/impressum Supervisory Board: Reiner Block (Chairman) Managing Directors: Ferdinand Neuwieser (Spokesperson), Christian Bauerschmidt, Thomas Kainz Phone: +49 89 5791 - 2534 Fax: +49 89 5791 - 2513 www.tuev - sued.de/is TÜV SÜD Industrie Service GmbH Civil engineering Munich Westendstraße 199 80686 Munich Germany Test Report: Containment Systems Munich MUC Westendstraße 199 80686 Munich Martin Kneißl Bm Sj 089 57912580 18 July 2018 Client Blobel Umwelttechnik GmbH Henleinstrasse 29a 86368 Gersthofen, Germany Test objects Designation: Containment systems / Retention bar- riers (Category 3: automatic, fixed, rotatable) Designation (dimensions): Type BL/BED - PM (250x30) Designation (dimensions): Type BL/BDD - PM (250x30) Order Participation in the leak testing of mobile containment systems for firefighting water retention based on VdS Guidelines 2564 - 1 Test result Leaktightness Type BL/BED - PM : 0 ml/m/h ( < 50 ml/m/h) Leaktightness Type BL/BDD - PM : 37 ml/m/h ( < 50 ml/m/h) Authors/contact Dipl. - Ing. Martin Beike Project number 1180345 - K3 - 30 / 2931886 Test date Report completi on 16 August 2018 and 28 September 20 1 8 16/11/2018 Scope of report 3 pages Type BL/BED - PM Type BL/BDD - PM

Views

  • 61 Total Views
  • 56 Website Views
  • 5 Embeded Views

Actions

  • 0 Social Shares
  • 0 Likes
  • 0 Dislikes
  • 0 Comments

Share count

  • 0 Facebook
  • 0 Twitter
  • 0 LinkedIn
  • 0 Google+